English
Language : 

TC1724 Datasheet, PDF (52/134 Pages) Infineon Technologies AG – 32-Bit Single-Chip Microcontroller
TC1724
Electrical Parameters
5.1.5 Operating Conditions
The following operating conditions must not be exceeded in order to ensure correct
operation and reliability of the TC1724. All parameters specified in the following tables
refer to these operating conditions, unless otherwise noticed.
Digital supply voltages applied to the TC1724 from external must be static regulated
voltages which allow a typical voltage swing of ± 5 %.
All parameters specified in the following tables refer to these operating conditions
(Table 14), unless otherwise noticed in the Note / Test Condition column.
Table 14 Operating Conditions Parameters
Parameter
Symbol
Min.
Values
Typ Max.
.
Unit Note /
Test Condition
Overload coupling
factor for analog
inputs, negative
KOVAN CC −
− 0.0001
IOV≥ -2 mA;
IOV≤ 0 mA; analog
pad= 5.0 V
Overload coupling
factor for analog
inputs, positive
KOVAP CC −
− 0.00001
IOV≥ 0 mA;
IOV≤ 3 mA; analog
pad= 5.0 V
CPU Frequency
fCPU SR −
− 133
MHz
SAK-TC1724F-
192F133HL;
SAK-TC1724F-
192F133HR;
SAK-TC1724N-
192F133HR
−
− 80
MHz
SAK-TC1724N-
192F80HL;
SAK-TC1724N-
192F80HR
Data Sheet
5-7
V1.2, 2014-06