Electrical Parameters
Table 28 Reset Timings Parameters (cont’d)
Parameter
Symbo
Values
Uni Note / Test Condition
l
Min. Typ. Max. t
TESTMODE / TR tPOH
100
−
−
ns
ST hold time from SR
PORST rising
edge
PORST rise time tPOR
−
SR
− 50
ms
TESTMODE / TR tPOS
0
−−
ns
ST setup time to SR
PORST rising
edge
Application Reset
inactive after
PORST
deassertion
tPOR_APP −
SR
−
40 7) μs
1) The duration of the boot time is defined between the rising edge of the internal application reset and the clock
cycle when the first user instruction has entered the CPU pipeline and its processing starts.
2) The given time includes the time of the internal reset extension for a configured value of
SCU_RSTCNTCON.RELSA = 0x05BE.
3) The duration of the boot time is defined between the rising edge of the PORST and the clock cycle when the
first user instruction has entered the CPU pipeline and its processing starts.
4) The given time includes the internal reset extension time for the System and Application Reset which is visible
through ESR0.
5) This parameter includes the delay of the analog spike filter in the PORST pad.
6) This parameter represents the additional time required to ensure that external crystal is stable and operational
at PORST.
7) Application Reset is assumed not to be extended from external, otherwise the time extends by the time the
Application Reset is extended.