English
Language : 

TLE75080-EMH Datasheet, PDF (49/80 Pages) Infineon Technologies AG – SPI Driver for Enhanced Relay Control
TLE75080-EMH
Protection Functions
switched ON after clearing the protection latch by setting the corresponding HWCR_OCL.OUTn bit to “1”. This bit is
set back to “0” internally after de-latching the channel.
8.3
Over Temperature and Over Load Protection in Limp Home mode
When TLE75080-EMH is in Limp Home mode, channels 2 and 3 can be switched ON using the input pins. In case
of Over Load, Short Circuit or Over Temperature the channels switch OFF. If the input pins remain “high”, the
channels restart with the following timings:
• 10 ms (first 8 retries)
• 20 ms (following 8 retries)
• 40 ms (following 8 retries)
• 80 ms (as long as the input pin remains “high” and the error is still present)
If at any time the input pin is set to “low” for longer than 2*tSYNC, the restart timer is reset. At the next channel
activation while in Limp Home mode the timer starts from 10 ms again. See Figure 21 for details. Over Load
current thresholds behave as described in Chapter 8.1.
IN0
IN1
IL2
IL3
0
1
8
1
8
1
8
t
0
1
t RETRY0(LH)
10 ms
tRETRY 1(LH)
20 ms
t RETRY2(LH)
40 ms
Figure 21 Restart timer in Limp Home mode
tRETRY 3(LH)
80 ms
tRETRY 0(LH)
t
10 ms
LHrestart.emf
8.4
Reverse Polarity Protection
In Reverse Polarity (also known as Reverse Battery) condition, High-Side channels have Reversave™
functionality. Each ESD diode of the logic and supply pins contributes to total power dissipation. Channels with
Reversave™ functionality are switched ON almost with the same RDS(ON) (see parameter RDS(REV)). The reverse
current through the channels has to be limited by the connected loads. The current through digital power supply
VDD and input pins has to be limited as well (please refer to the Absolute Maximum Ratings listed on Chapter 4.1).
Note: No protection mechanism like temperature protection or current limitation is active during reverse polarity.
8.5
Over Voltage Protection
In the case of supply voltages between VS(SC) and VS(LD) the output transistors are still operational and follow the
input pins or the OUT register.
In addition to the output clamp for inductive loads as described in Chapter 7.1.2, there is a clamp mechanism
available for over voltage protection for the logic and all channels, monitoring the voltage between VS and GND
pins (VS(AZ)).
Data Sheet
49
Rev. 1.0, 2016-06-22