TLE75080-EMH Datasheet, PDF (30/80 Pages) Infineon Technologies AG – SPI Driver for Enhanced Relay Control
TLE75080-EMH
Power Supply
6.1.6 Definition of Power Supply modes transition times
The channel turn-ON time is as defined by parameter tON when TLE75080-EMH is in Active mode or in Limp Home
mode. In all other cases, it is necessary to add the transition time required to reach one of the two aforementioned
Power Supply modes (as shown in Figure 13).
init
tSLEEP2IDLE
tIDLE2SLEEP
Sleep
tLH2SLEEP
tSLEEP2LH
Idle
tACTIVE2SLEEP
Channel ON
tON Limp Home
tACTIVE2IDLE
tIDLE2ACTIVE
Figure 13 Transition Time diagram
tON
Active
tLH2ACTIVE
tACTIVE2LH
OpModesTimings.emf
6.2
Reset condition
One of the following 3 conditions resets the SPI registers to the default value:
• VDD is not present or below the undervoltage threshold VDD(UV)
• IDLE pin is set to “low”
• a reset command (HWCR.RST set to “1”) is executed
– ERRn bits are not cleared by a reset command (for functional safety)
– UVRVS and LOPVDD bits are cleared by a reset command
In particular, all channels are switched OFF (if there are no input pin set to “high”) and the Input Mapping
configuration is reset.
6.2.1
Undervoltage on VS
Between VS(UV) and VS(OP) the undervoltage mechanism is triggered. If the device is operative and the supply
voltage drops below the undervoltage threshold VS(UV), the logic set the bit UVRVS to “1”. As soon as the supply
voltage VS is above the minimum voltage operative threshold VS(OP), the bit UVRVS is set to “0” after the first
Standard Diagnosis readout. Undervoltage condition on VS influences the status of the channels, as described in
Table 6. Figure 14 sketches the undervoltage behavior (the “VS - VDS” line refers to a channel which is
programmed to be ON).
Data Sheet
30