TLE9221SX
Power Supply Interface
V
uVBAT
uBDUVBAT
uBDUVVCC
uVCC
uVIO
uBDPDBAT
dBDPowerUp
BD_Off
powering up the
Central State Machine
Interim_BD_Standby
Host Interface blocked
t
BD_Standby
Host Interface released
Figure 30 Power-up
8.4.3 Interim BD_Standby Mode
As a safety measure, the TLE9221SX provides an Interim BD_Standby mode. Changeover to the
Interim_BD_Standby mode takes place during an incomplete power-up procedure (see Figure 31).
In Interim_BD_Standby mode, the TLE9221SX provides the same functions as in BD_Standby mode, except for
the host commands. The host commands are blocked in Interim BD_Standby mode. Therefore, a host command
cannot be used to change the mode of the TLE9221SX, while the power-up has not completed. With switching
over to the interim BD_Standby mode, at least one undervoltage detection timer is started. In case the power-up
is completed before the undervoltage detection timer expires, the TLE9221SX changes the mode of operation to
BD_Standby mode. In case the undervoltage detection timer expires before the power-up is completed, the
undervoltage flag is set depending on which power supply is missing, and the mode of operation changes to low
power mode (compare with Chapter 9.3).