Power Supply Interface
Interface are blocked as long as the uVBAT undervoltage flag remains active (compare also with Chapter 9.3 and
Table 14).
ERRN
dReactionTimeERRN
t
uVBAT
set uVBAT undervoltage bit
set error bit
dBDUVVBAT_BLK
uBDUVVBAT (Threshold)
dBDUVVBAT_Hys
t < dBDUVVBAT_BLK
dBDUVVBAT
set uVBAT undervoltage flag,
block host commands
non-low power mode
t
dBDRVBAT
clear uVBAT undervoltage flag,
release host commands
(return to the mode of operation
selected by the host command)
BD_Sleep
Figure 26 Undervoltage event at uVBAT in non-low power mode
8.3.3
Undervoltage Event at uVCC
Power supply voltage fluctuations on the uVCC power supply, falling below the threshold uBDUVVCC for a time
longer than the blanking time dBDUVVCC_BLK, are considered as undervoltage events. Voltage fluctuations on
uVCC shorter than the time dBDUVCC_BLK are ignored and not recognized by the Power Supply Interface.
Detecting an undervoltage event on uVCC, the FlexRay transceiver TLE9221SX sets the uVCC undervoltage bit
(bit 9) and the error bit (bit 11) (see Figure 27). After the uVCC undervoltage detection timer dBDUVVCC expires,
the uVCC undervoltage flag is set, the mode of operation changes to BD_Standby mode.
The Host Interface remains active while the uVCC undervoltage detection timer is running and the reference supply
uVIO is present. Setting the uVCC undervoltage flag blocks the Host Interface and forces the mode of operation to
BD_Standby mode (compare also with Chapter 9.3 and Table 14).
While the power supply uVCC is in undervoltage condition, the TLE9221SX also disables the Transmitter and sets
the bus error bit (bit 4).