TLE9221SX
t
ERRN
uVIO
set all output pins “low”
set all input pins to default
block all host commands
dReactionTimeERRN
set uVIO undervoltage bit
set error bit
Power Supply Interface
t
uUVIO (Threshold)
uUVIO_Hys
t < dBDUVVIO_BLK
dBDUVVIO_BLK
W
G%'59,2
dBDModeChange
dBDUVVIO
set uVIO undervoltage flag
clear uVIO undervoltage flag,
release host commands
(return to the mode of operation
selected by the host command)
QRQORZSRZHUPRGH
%'B6WDQGE\
%'B6OHHS
Figure 28 Undervoltage event at uVIO in non-low power mode
Note: While the TLE9221SX is in undervoltage condition at the reference supply uVIO, all digital outputs are set to
“low”. The outputs do not reflect the status of the transceiver anymore.
For example, wake-up events cannot be indicated at the ERRN, RxD, and RxEN output anymore, since
these outputs are set permanently to “low”.
8.4
Power-up and Power-down
8.4.1 BD_Off State
According to the FlexRay Electrical Physical Layer Specification, version 3.0.1, BD_Off state is reached, when the
transceiver does not receive any supply.
The transceiver TLE9221SX is in BD_Off state when the internal supply voltage uVIN is turned off and the Central
State Machine is powered down. When both power supplies, uVCC and uVBAT fall below their power-down
thresholds (uBDPDVBAT and uBDPDVCC), the internal supply is off and the BD_Off state is reached (see
Figure 29).
The status of the reference supply uVIO has no influence on the power-down sequence of the Flexray transceiver
TLE9221SX.
When the FlexRay transceiver TLE9221SX is in BD_Off state, all outputs are logical “low”, the Transmitter and the
Receiver are turned off and the wake-up functions are not operational. If the reference supply uVIO is available,
the inputs are set to their default values (compare with Table 2).
Data Sheet
38