TLE9221SX Datasheet, PDF (37/91 Pages) Infineon Technologies AG – FlexRay Transceiver
TLE9221SX
Power Supply Interface
ERRN
dReactionTimeERRN
t
uVCC
set uVCC undervoltage bit
set error bit
dBDUVVCC_BLK
uBDUVVCC (Threshold)
uBDUVVCC_Hys
t < dBDUVVCC_BLK
dBDUVVCC
set uVCC undervoltage flag,
block host commands
non-low power mode
t
dBDRVCC
clear uVCC undervoltage flag,
release host commands
(return to the mode of operation
selected by the host command)
BD_Standby
Figure 27 Undervoltage event at uVCC in non-low power mode
8.3.4
Undervoltage Event at uVIO
The Central State Machine of the TLE9221SX handles an undervoltage event at the reference supply uVIO in a
manner identical to an undervoltage event on the power supply uVBAT.
The supply on the level shift input VIO is the main reference for all digital inputs and outputs of the TLE9221SX. It
is also connected to the pad supply of the external microcontroller (see Figure 50). An undervoltage event on the
level shift input VIO could lead to a misinterpretation of the digital input levels and could generate a false signal at
the digital outputs.
For fail-safe reasons, the TLE9221SX blocks the Host Interface, the Communication Controller Interface and the
Bus Guardian Interface after a small processing time (dReactionTimeERRN) when an undervoltage event has been
detected on the reference supply uVIO (see Figure 28). According to Table 2, all digital inputs are set to their
default level. All digital outputs are set to logical “low”.
The transceiver TLE9221SX detects an undervoltage event, if the supply at the pin VIO drops for the time period
t > dBDUVVIO_BLK below the undervoltage detection threshold uUVIO (see Figure 28). Voltage fluctuations on uVIO
shorter than dBDUVCC_BLK are ignored and not recognized by the Power Supply Interface.
Although the Host Interface is blocked and the SIR is not accessible while the reference supply uVIO is in
undervoltage condition, the transceiver sets the uVIO undervoltage bit (bit 10) and the error bit (bit 11) (see
Figure 28). After the uVIO undervoltage detection timer dBDUVVIO expires, the uVIO undervoltage flag is set and
the mode of operation changes to BD_Sleep mode (compare also to Chapter 9.3 and Table 14).