English
Language : 

TC1775 Datasheet, PDF (35/101 Pages) Infineon Technologies AG – 32-Bit Single-Chip Microcontroller
TC1775
Preliminary
Timer Units
The TC1775 includes two timer units:
– General Purpose Timer Unit (GPTU)
– General Purpose Timer Array (GPTA)
General Purpose Timer Unit
Figure 9 shows a global view of all functional blocks of the General Purpose Timer Unit
(GPTU) module.
C lo c k
Control
fGPTU
Address
Decoder
SR0
SR1
SR2
SR3
Interrupt
Control
SR4
SR5
SR6
SR7
GPTU
M odule
(K e rn e l)
IN 0
IO 0
IN 1
IN 2
IO 1
IN 3
IN 4
IO 2
IN 5
IN 6
IN 7
IO 3
P o rt
OUT0 Control IO4
OUT1
OUT2
IO 5
OUT3
OUT4
OUT5
IO 6
OUT6
OUT7
IO 7
P13.0 / G PT0
P13.1 / G PT1
P13.2 / G PT2
P13.3 / G PT3
P13.4 / G PT4
P13.5 / G PT5
P13.6 / G PT6
P13.7 / G PT7
M C B04489
Figure 9 General Block Diagram of the GPTU Interface
The GPTU consists of three 32-bit timers designed to solve such application tasks as
event timing, event counting, and event recording. The GPTU communicates with the
external world via eight inputs and eight outputs located at Port 13.
The three timers of the GPTU module (T0, T1, and T2) can operate independently from
each other, or can be combined:
General Features:
• All timers are 32-bit precision timers with a maximum input frequency of fGPTU
• Events generated in T0 or T1 can be used to trigger actions in T2
• Timer overflow or underflow in T2 can be used to clock either T0 or T1
• T0 and T1 can be concatenated to form one 64-bit timer
Data Sheet
31
V1.2, 2002-05