English
Language : 

TLE9260-3QX Datasheet, PDF (151/175 Pages) Infineon Technologies AG – Dedicated Data Sheets are available for the different product variants
TLE9260-3QX
Serial Peripheral Interface
SUP_STAT_1
Supply Voltage Fail Status (Address 100 0001B)
POR / Soft Reset Value: y000 0000B; Restart Value: xxxx xx0xB
7
6
5
4
3
2
1
0
POR
rc
VSHS_UV
rc
VSHS_OV
rc
VCC2_OT
rc
VCC2_UV
rc
VCC1_SC VCC1_UV_FS VCC1_UV
r
rc
rc
rc
Field
Bits
POR
7
VSHS_UV 6
VSHS_OV 5
VCC2_OT 4
VCC2_UV 3
VCC1_SC 2
VCC1_UV 1
_FS
VCC1_UV 0
Type
rc
rc
rc
rc
rc
rc
rc
rc
Description
Power-On Reset Detection
0B , No POR
1B , POR occurred
VSHS Under-Voltage Detection (VSHS,UVD)
0B , No VSHS-UV
1B , VSHS-UV detected
VSHS Over-Voltage Detection (VSHS,OVD)
0B , No VSHS-OV
1B , VSHS-OV detected
VCC2 Over Temperature Detection
0B , No over temperature
1B , VCC2 over temperature detected
VCC2 Under Voltage Detection (VCC2,UV,f)
0B , No VCC2 Under voltage
1B , VCC2 under voltage detected
VCC1 Short to GND Detection (<Vrtx for t>4ms after switch on)
0B , No short
1B , VCC1 short to GND detected
VCC1 UV-Detection (due to Vrtx reset)
0B , No Fail-Safe Mode entry due to 4th consecutive VCC1_UV
1B , Fail-Safe Mode entry due to 4th consecutive VCC1_UV
VCC1 UV-Detection (due to Vrtx reset)
0B , No VCC1_UV detection
1B , VCC1 UV-Fail detected
Notes
1. The MSB of the POR/Soft Reset value is marked as ‘y’: the default value of the POR bit is set after Power-on
reset (POR value = 1000 0000). However it will be cleared after a SBC Soft Reset command (Soft Reset value
= 0000 0000).
2. During Sleep Mode, the bits VCC1_SC,VCC1_OV and VCC1_UV will not be set when VCC1 is off
3. The VCC1_UV bit is never updated in SBC Restart Mode, in SBC Init Mode it is only updated after RO was
released for the first time, it is always updated in SBC Normal and Stop Mode, and it is always updated in any
SBC modes in a VCC1_SC condition (after VCC1_UV = 1 for >4ms).
Data Sheet
151