TLE9260-3QX Datasheet, PDF (120/175 Pages) Infineon Technologies AG – Dedicated Data Sheets are available for the different product variants
TLE9260-3QX
Serial Peripheral Interface
HW_CTRL
Mode- and Supply Control (Address 000 0010B)
POR / Soft Reset Value: 0000 0000B; Restart Value: 0x00 000xB
7
6
5
4
3
2
1
Reserved
SOFT_RESET
_RO
r
rw
FO_ON
rwh
Reserved
r
Reserved
r
Reserved Reserved
r
r
r
0
CFG
rw
Field
Bits
Reserved 7
SOFT_
6
RESET_RO
FO_ON
5
Reserved 4
Reserved 3
Reserved 2
Reserved 1
CFG
0
Type
r
rw
rwh
r
r
r
r
rw
Description
Reserved, always reads as 0
Soft Reset Configuration
0B , RO will be triggered (pulled low) during a Soft Reset
1B , No RO triggering during a Soft Reset
Failure Output Activation (FO1..3)
0B , FOx not activated by software, FO can be activated by defined
failures (see Chapter 12)
1B , FOx activated by software (via SPI)
Reserved, always reads as 0
Reserved, always reads as 0
Reserved, always reads as 0
Reserved, always reads as 0
Configuration Select (see also Table 5)
0B , Depending on hardware configuration, SBC Restart or Fail-
Safe Mode is reached after the 2. watchdog trigger failure
(=default) - Config 3/4
1B , Depending on hardware configuration, SBC Restart or Fail-
Safe Mode is reached after the 1. watchdog trigger failure -
Config 1/2
Notes
1. Clearing the FO_ON bit will not disable the FOx outputs for the case a failure occurred which triggered the FOx
outputs. In this case the FOx outputs have to be disabled by clearing the FAILURE bit.
If the FO_ON bit is set by the software then it will be cleared by the SBC after SBC Restart Mode was entered
and the FOx outputs will be disabled. See also Chapter 12 for FOx activation and deactivation.
Data Sheet
120
Rev. 1.1, 2014-09-26