TLE9260-3QX Datasheet, PDF (105/175 Pages) Infineon Technologies AG – Dedicated Data Sheets are available for the different product variants
TLE9260-3QX
Supervision Functions
13.9
Thermal Protection
Three independent and different thermal protection features are implemented in the SBC according to the system
impact:
• Individual thermal shutdown of specific blocks
• Temperature prewarning of main microcontroller supply VCC1
• SBC thermal shutdown due to VCC1 over temperature
13.9.1 Individual Thermal Shutdown
As a first-level protection measure the output stages VCC2, CAN, and HSx are independently switched OFF if the
respective block reaches the temperature threshold TjTSD1. Then the TSD1 bit is set. This bit can only be cleared
via SPI once the overtemperature is not present anymore. Independent of the SBC Mode the thermal shutdown
protection is only active if the respective block is ON.
The respective modules behave as follows:
• VCC2: Is switched to OFF and the control bits VCC2_ON are cleared. The status bit VCC2_OT is set. Once
the over temperature condition is not present anymore, then VCC2 has to be configured again by SPI.
• CAN: The transmitter is disabled and stays in CAN Normal Mode acting like CAN Receive only mode. The
status bits CAN_FAIL = ‘01’ are set. Once the over temperature condition is not present anymore, then the
CAN transmitter is automatically switched on.
• HSx: If one or more HSx switches reach the TSD1 threshold, then all HSx switches are turned OFF and the
control bits for HSx are cleared (see registers HS_CTRL1 and HS_CTRL2). The status bits HSx_OC_OT are
set (see register HS_OC_OT_STAT). Once the over temperature condition is not present anymore, then HSx
has to be configured again by SPI.
Note: The diagnosis bits are not cleared automatically and have to be cleared via SPI once the overtemperature
condition is not present anymore.
Data Sheet
105
Rev. 1.1, 2014-09-26