ELECTRICAL CONNECTIONS
STATIC ELECTRICAL CHARACTERISTICS
Table 5. Static Electrical Characteristics (continued)
Characteristics noted under conditions 6.0 V ≤ VPWR ≤ 27 V, 4.5 V ≤ VDD ≤ 5.5 V, -40°C ≤ TJ ≤ 150°C unless otherwise noted.
Typical values noted reflect the approximate parameter means at TA = 25°C under nominal conditions unless otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
LOW-SIDE POWER OUTPUTS
Drain-to-Source ON Resistance (IOUT = 0.3 A)
TJ = 25°C
VPWR = 4.5 V; VDD = 3.5 V, 33888A Only
VPWR = 6.0 V
VPWR = 9.0 V
VPWR = 13 V
TJ = 150°C
VPWR = 4.5 V; VDD = 3.5 V, 33888A Only
VPWR = 6.0 V
VPWR = 9.0 V
VPWR = 13 V
RDS(ON)
–
–
–
–
–
–
–
–
Ω
–
8.0
–
1.0
–
0.7
–
0.6
–
8.0
–
1.8
–
1.1
–
0.9
Output Self-Limiting Current (Outputs Programmed ON, VOUT = 3.0 V)
ILIM
Low-Side 4, 6, 8, 10
Low-Side 5, 7, 9, 11
A
0.5
0.9
1.5
0.8
1.3
2.0
Output OFF Open Load Detection Current (19)
Output Programmed OFF, VOUT = 3.0 V
IOLDC
µA
25
50
100
Output Fault Detection Threshold (20)
Output Programmed OFF
VOFD(THRES)
V
2.0
3.0
4.0
Output Clamp Voltage
2.0 mA < IOUT < 200 mA, Outputs OFF
VCL
V
41
53
60
Low-Side Body Diode Voltage (I = -300 mA, TJ = 125°C)
Overtemperature Shutdown (Outputs OFF) (21)
Overtemperature Shutdown Hysteresis (21)
VBD
0.5
0.7
0.9
V
TLIM
160
170
190
°C
TLIM(HYS)
10
20
30
°C
Notes
19. Output OFF Open Load Detection Current is the current required to flow through the load for the purpose of detecting the existence of
an open load condition when the specific output is commanded OFF.
20. Output fault detection threshold with outputs programmed OFF. For the low-side outputs, fault detection thresholds are the same for
output open and battery shorts.
21. Guaranteed by design. Not production tested.