English
Language : 

F81218 Datasheet, PDF (23/64 Pages) Feature Integration Technology Inc. – ISA/LPC to 6 UART Datasheet
F81218
Write the same value to enable the timer, write 0 to disable timer.
5.5 Serial IRQ
F81218 supports a serial IRQ scheme. This allows a signal line to be used to report the
legacy ISA interrupt requests. Because more than one device may need to share the signal serial
IRQ signal line, an open drain signal scheme is used. The clock source is the PCI clock. The
serial interrupt is transferred on the SERIRQ signal, one cycle consisting of three frames types: a
start frame, several IRQ/Data frame, and one Stop frame.
5.5.1 Start Frame
There are two modes of operation for the SERIRQ Start frame: Quiet mode and Continuous
mode. In the Quiet mode, the peripheral drives the SERIRQ signal active low for one clock, and
then tri-states it. This brings all the states machines of the peripherals from idle to active states.
The host controller will then take over driving SERIRQ signal low in the next clock and will continue
driving the SERIRQ low for programmable 3 to 7 clock periods. This makes the total number of
clocks low for 4 to 8 clock periods. After these clocks, the host controller will drive the SERIRQ high
for one clock and then tri-states it. In the Continuous mode, only the host controller initiates the
START frame to update IRQ/Data line information. The host controller drives the SERIRQ signal
low for 4 to 8 clock periods. Upon a reset, the SERIRQ signal is defaulted to the Continuous mode
for the host controller to initiate the first Start frame.
5.5.2 IRQ/Data Frame
Once the start frame has been initiated, all the peripherals must start counting frames based
on the rising edge of the start pulse. Each IRQ/Data Frame is three clocks: Sample phase,
Recovery phase, and Turn-around phase. During the Sample phase, the peripheral drives SERIRQ
low if the corresponding IRQ is active. If the corresponding IRQ is inactive, then SERIRQ must be
left tri-stated. During the Recovery phase, the peripheral device drives the SERIRQ high. During
the Turn-around phase, the peripheral device left the SERIRQ tri-stated. The IRQ/Data Frame has
a number of specific order , as shown in Table 5-1. The F81218 is only support IRQ3, IRQ4, IRQ5,
IRQ9, IRQ10, and IRQ11.
Table 5-1 IRQSER Sampling periods
-18-
August, 2007
V0.33P