English
Language : 

KX022-1020 Datasheet, PDF (52/75 Pages) List of Unclassifed Manufacturers – Accelerometer Specifications
± 2g / 4g / 8g Tri-axis Digital
Accelerometer Specifications
PART NUMBER:
KX022-1020
Rev. 11.0
10-Sep-15
HYST_SET
This register sets the Hysteresis that is placed in between the Screen Rotation states. The KX022
ships from the factory with HYST_SET set to ±15° of hysteresis. A different default hysteresis can be
requested from the factory. Note that when writing a new value to this register the current values of
RES0 and RES1 must be preserved. These values are set at the factory and must not change. Note
that to properly change the value of this register, the PC1 bit in CTRL_REG1 must first be set to “0”.
R/W
RES1
Bit7
R/W
RES0
Bit6
R/W
HYST5
Bit5
R/W
HYST4
Bit4
R/W
HYST3
Bit3
R/W
R/W
R/W
HYST2 HYST1 HYST0
Bit2
Bit1
Bit0
I2C Address: 0x34h
Reset Value
00010100
LP_CNTL
Low Power Control sets the number of samples of accelerometer output to be averaged. Note that to
properly change the value of this register, the PC1 bit in CTRL_REG1 must first be set to “0”.
R/W
Reserved
Bit7
R/W
AVC2
Bit6
R/W
AVC1
Bit5
R/W
AVC0
Bit4
R/W
R/W
R/W
R/W
Reserved Reserved Reserved Reserved
Bit3
Bit2
Bit1
Bit0
I2C Address: 0x35h
Reset Value
01001011
AVC<2:0> – Averaging Filter Control, the default setting is 16 samples averaged
000 = No Averaging
001 = 2 Samples Averaged
010 = 4 Samples Averaged
011 = 8 Samples Averaged
100 = 16 Samples Averaged (default)
101 = 32 Samples Averaged
110 = 64 Samples Averaged
111 = 128 Samples Averaged
36 Thornwood Dr. – Ithaca, NY 14850
tel: 607-257-1080 – fax:607-257-1146
www.kionix.com - info@kionix.com
© 2015 Kionix – All Rights Reserved
Page 52 of 75