OWUF2, OWUF1, OWUF0 sets the output data rate for the general motion detection function
and the high-pass filtered outputs per Table 20. The default Motion Wake Up ODR is
0.781Hz.
OWUF2 OWUF1 OWUF0 Output Data Rate
0
0
0
0.781Hz
0
0
1
1.563Hz
0
1
0
3.125Hz
0
1
1
6.250Hz
1
0
0
12.5Hz
1
0
1
25Hz
1
1
0
50Hz
1
1
1
100Hz
Table 20: Motion Wake Up Function Output Data Rate