English
Language : 

W77E532 Datasheet, PDF (20/86 Pages) Winbond – 8 BIT MICROCONTROLLER
W77E532/W77E532A
Software Reset
Set CHPCON = 0X83, timer and enter IDLE mode. CPU will reset and restart from APFLASH after time
out.
Port 2
Bit:
7
6
5
4
3
2
1
0
P2.7 P2.6 P2.5 P2.4 P2.3 P2.2 P2.1 P2.0
Mnemonic: P2
Address: A0h
P2.7-0: Port 2 is a bi-directional I/O port with internal pull-ups. This port also provides the upper
address bits for accesses to external memory.
Port 4 Chip-select Polarity
Bit:
7
6
5
4
3
2
1
0
P43INV P42INV P42INV P40INV -
-
-
P0UP
Mnemonic: P4CSIN
Address: A2h
P4xINV: The active polarity of P4.x when set it as chip-select signal. High = Active High. Low = Active
Low.
P0UP: Enable Port 0 weak pull up.
Port 4
Bit:
7
6
5
4
3
2
1
0
-
-
-
-
P4.3 P4.2 P4.1 P4.0
Mnemonic: P4
Address: A5h
P4.3-0: Port 4 is a bi-directional I/O port with internal pull-ups. Port 4 can not use bit-addressable
instruction (SETB or CLR).
Interrupt Enable
Bit:
7
6
5
4
3
2
1
0
EA
ES1 ET2
ES
ET1 EX1 ET0 EX0
Mnemonic: IE
Address: A8h
EA: Global enable. Enable/disable all interrupts except for PFI.
ES1: Enable Serial Port 1 interrupt.
ET2: Enable Timer 2 interrupt.
ES: Enable Serial Port 0 interrupt.
ET1: Enable Timer 1 interrupt
EX1: Enable external interrupt 1
ET0: Enable Timer 0 interrupt
EX0: Enable external interrupt 0
- 20 -
Publication Release Date: June 30, 2009
Revision A10