English
Language : 

LM3S8971 Datasheet, PDF (279/577 Pages) List of Unclassifed Manufacturers – Microcontroller
LM3S8971 Microcontroller
Register 11: ADC Sample Sequence Input Multiplexer Select 0 (ADCSSMUX0),
offset 0x040
This register defines the analog input configuration for each sample in a sequence executed with
Sample Sequencer 0.
This register is 32-bits wide and contains information for eight possible samples.
ADC Sample Sequence Input Multiplexer Select 0 (ADCSSMUX0)
Base 0x4003.8000
Offset 0x040
Type R/W, reset 0x0000.0000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
reserved
MUX7
reserved
MUX6
reserved
MUX5
reserved
MUX4
Type RO
R/W
R/W
R/W
RO
R/W
R/W
R/W
RO
R/W
R/W
R/W
RO
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
MUX3
reserved
MUX2
reserved
MUX1
reserved
MUX0
Type RO
R/W
R/W
R/W
RO
R/W
R/W
R/W
RO
R/W
R/W
R/W
RO
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit/Field
31
30:28
27
26:24
23
22:20
19
Name
reserved
MUX7
reserved
MUX6
reserved
MUX5
reserved
Type
RO
R/W
RO
R/W
RO
R/W
RO
Reset
0
0
0
0
0
0
0
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
8th Sample Input Select
The MUX7 field is used during the eighth sample of a sequence executed
with the Sample Sequencer. It specifies which of the analog inputs is
sampled for the analog-to-digital conversion. The value set here indicates
the corresponding pin, for example, a value of 1 indicates the input is
ADC1.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
7th Sample Input Select
The MUX6 field is used during the seventh sample of a sequence
executed with the Sample Sequencer and specifies which of the analog
inputs is sampled for the analog-to-digital conversion.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
6th Sample Input Select
The MUX5 field is used during the sixth sample of a sequence executed
with the Sample Sequencer and specifies which of the analog inputs is
sampled for the analog-to-digital conversion.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
October 01, 2007
279