English
Language : 

EP2AGX260EF29I3N Datasheet, PDF (35/78 Pages) Altera Corporation – Device Datasheet for Arria II Devices
Chapter 1: Device Datasheet for Arria II Devices
Switching Characteristics
1–35
Table 1–37 lists the typical VOD for TX term that equals 100 . for Arria II GX and GZ
devices.
Table 1–37. Typical VOD Setting, TX Termination = 100  for Arria II Devices
Quartus II Setting
1
VOD Setting (mV)
400
2
600
3 (Arria II GZ)
700
4
800
5
900
6
1000
7
1200
Table 1–38 lists the typical transmitter pre-emphasis levels in dB for the first post tap
under the following conditions: low-frequency data pattern (five 1s and five 0s) at
6.375 Gbps. The levels listed in Table 1–38 are a representation of possible
pre-emphasis levels under these specified conditions only, the pre-emphasis levels
may change with data pattern and data rate.
To predict the pre-emphasis level for your specific data rate and pattern, run
simulations using the Arria II GX HSSI HSPICE models.
Table 1–38. Transmitter Pre-Emphasis Levels for Arria II GX Devices
Arria II GX
(Quartus II
Software)
First Post Tap
1
Setting
0 (off)
0
1
0.7
2
2.7
3
4.9
4
7.5
5
—
6
—
Arria II GX (Quartus II Software) VOD Setting
2
4
5
6
0
0
0
0
0
0
0
0
1.2
0.3
0
0
2.4
1.2
0.8
0.5
3.8
2.1
1.6
1.2
5.3
3.1
2.4
1.8
7
4.3
3.3
2.7
7
Unit
0
—
0
dB
0
dB
0.2
dB
0.6
dB
1.1
dB
1.7
dB
December 2013 Altera Corporation