AKD4122A-A Datasheet, PDF (23/37 Pages) Asahi Kasei Microsystems – Evaluation board Rev.0 for AK4122A | |||
|
◁ |
MEASUREMENT RESULTS
[Measurement condition]
⢠Measurement unit : Audio Precision, System Two Cascade
⢠Power Supply
: AVDD = DVDD = 3.3V
⢠Band width
: 10Hz â¼ FSO/2
⢠Temperature
: Room
⢠Measurement Path : AK4122A PORT1 â SRC â AK4122A PORT3
[Measurement Result]
SRC Characteristics
THD+N
(Input = 1kHz, 0dBFS)
FSO/FSI = 44.1kHz/48kHz
FSO/FSI = 48kHz/44.1kHz
FSO/FSI = 32kHz/48kHz
FSO/FSI = 96kHz/32kHz
Worst Case (FSO/FSI = 48kHz/8kHz)
Dynamic Range (Input = 1kHz, â60dBFS)
FSO/FSI = 44.1kHz/48kHz
FSO/FSI = 48kHz/44.1kHz
FSO/FSI = 32kHz/48kHz
FSO/FSI = 96kHz/32kHz
Worst Case (FSO/FSI = 32kHz/44.1kHz)
Dynamic Range (Input = 1kHz, â60dBFS, A-weighted)
FSO/FSI = 44.1kHz/48kHz
Result
113.5
113.4
114.2
113.2
111.7
115.1
115.1
115.3
115.2
115.5
117.2
[AKD4122A-A]
Unit
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
<KM099400>
- 23 -
2009/03
|
▷ |