English
Language : 

AKD4122A-A Datasheet, PDF (21/37 Pages) Asahi Kasei Microsystems – Evaluation board Rev.0 for AK4122A
[AKD4122A-A]
Control Software Manual
„ Set-up of evaluation board and control software
1. Set up the AKD4122A-A according to previous term.
2. Connect IBM-AT compatible PC with AKD4122A-A by 10-line type flat cable (packed with AKD4122A-A).
Take care of the direction of 10pin header. (Please install the driver in the CD-ROM when this control software is
used on Windows 2000/XP. Please refer “Installation Manual of Control Software Driver by AKM device control
software”. In case of Windows95/98/ME, this installation is not needed. This control software does not operate on
Windows NT.)
3. Insert the CD-ROM labeled “AK4122A Evaluation Kit” into the CD-ROM drive.
4. Access the CD-ROM drive and double-click the icon of “AKD4122A-A.exe” to set up the control program.
5. Then please evaluate according to the follows.
„ Operation flow
Keep the following flow.
1. Set up the control program according to explanation above.
2. Click “Port Setup” button.
3. Click “Write default” button.
Then set up the dialog and input data.
„ Explanation of each buttons
1. [Port Setup] : Set up the printer port.
2. [Write default] : Initialize the register of AK4122A.
3. [All Read] : Read the all register of AK4122A.
4. [Function1] : Dialog to write data by keyboard operation.
5. [Write] :
Dialog to write data by mouse operation.
6. [Read] :
Read each register data by mouse operation.
„ Explanation of each dialog
1. [Function1 Dialog] : Dialog to write data by keyboard operation
Address Box: Input register address in 2 figures of hexadecimal.
Data Box:
Input register data in 2 figures of hexadecimal.
If you want to write the input data to AK4122A, click “OK” button. If not, click “Cancel” button.
2. [Write Dialog] : Dialog to write data by mouse operation
There are dialogs corresponding to each register.
Click the “Write” button corresponding to each register to set up the dialog. If you check the check box, data
becomes “H” or “1”. If not, “L” or “0”.
If you want to write the input data to AK4122A, click “OK” button. If not, click “Cancel” button.
<KM099400>
- 21 -
2009/03