English
Language : 

AK8851 Datasheet, PDF (10/80 Pages) Asahi Kasei Microsystems – NTSC/PAL/SECAM Digital Video Decoder
ASAHI KASEI
(3-2) 16-Bit Output Data Timing ([D7:D0] and [EXTDAT7:EXTDAT0])
HALFCKO
[D7:0]
EXTDAT7:0]
tOSU3
tOHD3
Y Cb/Cr
Parameter
Symbol
Min.
Typ.
Max.
Output Data Setup Time tOSU3
10
Output Data Hold Time tOHD3
20
(4) Reset Timing
[AK8851]
VIH
VIL
VIH
VIL
Units
nsec
nsec
Remark
CLClk 25pF
CLData 25pF
/RESET
CLK
VIL
pRES
Parameter
Symbol
Min.
Typ.
Max.
Units
Remark
/RESET Pulse width
pRES
10
CLK
Clock Rising Edge
Note) a 24.576 MHz clock is required for reset operation.
After application of clock, the /RESET pin should be pulled low. This power-on RESET is recommended whenever
power is applied or removed from the AK8851, until as applying voltage to the AK8851 cannot ensure proper device
initialization. Only a reset sequence can ensure this.
.
Output pins except for CLK27MO pin become low during the reset sequence.
MS0244-E-03
10
Confidential
2005 / 07