English
Language : 

W83627HF Datasheet, PDF (68/185 Pages) Winbond – WINBOND I/O
W83627HF/F
PRELIMINARY
5.1.8 Bank0.Reg7 - User Defined Register (UDR/AUDR)
Power on default <7:0> = 0000,0000 binary
Bit
Name
Read/Write
Description
7 RXACT
Read/Write
Receive Active. Set to 1 whenever a pulse or pulse-train is
detected by the receiver. If a 1 is written into the bit
position, the bit is cleared and the receiver is de-actived.
When this bit is set, the receiver samples the IR input
continuously at the programmed baud rate and transfers
the data to the receiver FIFO.
6 RX_PD
Read Only
Set to 1 whenever a pulse or pulse-train (modulated pulse)
is detected by the receiver. Can be used by the sofware to
detect idle condition Cleared Upon Read.
5 Reserved
-
-
4-0 FOLVAL
Read Only
FIFO Level Value. Indicate that how many bytes are there
in the current received FIFO. Can read these bits then get
the FIFO level value and successively read RBR by the
prior value.
- 58 -
Publication Release Date: Sep 1998
Revision 0.50