English
Language : 

W83627HF Datasheet, PDF (143/185 Pages) Winbond – WINBOND I/O
W83627HF/F
7 65432 1 0
PRELIMINARY
STOP3
INTMOD
Reserved
FAULT
FAULT
Reserved
Reserved
Reserved
Bit 7-5: Read - Reserved. This bit should be set to 0.
Bit 4-3: Read/Write - Number of faults to detect before setting OVT# output to avoid false tripping
due to noise.
Bit 2: Read - Reserved. This bit should be set to 0.
Bit 1: Read/Write - OVT# Interrupt Mode select. This bit default is set to 0, which is Compared Mode.
When set to 1, Interrupt Mode will be selected.
Bit 0: Read/Write - When set to 1 the sensor will stop monitor.
11.7.41 Temperature Sensor 3 Hysteresis (High Byte) Register - Index 53h (Bank 2)
Register Location:
53h
Power on Default Value
4Bh
Attribute:
Read/Write
Size:
8 bits
7 65 432 1 0
THYST3<8:1>
Bit 7-0: Temperature hysteresis bit 8-1, which is High Byte. The temperature default 75 degree C.
11.7.42 Temperature Sensor 3 Hysteresis (Low Byte) Register - Index 54h (Bank 2)
Register Location:
54h
Power on Default Value
00h
Attribute:
Read/Write
Size:
8 bits
- 126 -
Publication Release Date: Jul 1999
Revision 0.53