English
Language : 

TA1317AFG Datasheet, PDF (35/58 Pages) Toshiba Semiconductor – Deflection Processor IC for TV
Note
No.
Parameter
16 Horizontal amplitude
adjustment (picture width)
change amount
17 Parabola amplitude
adjustment (EW parabola)
change amount
TA1317AFG
SW6
OFF
OFF
SW7
B
B
SW8
ON
ON
Test Condition
SW Mode
SW10 SW13 SW14 SW21 SW30
Test Method
(unless otherwise specified, VCC = 9 V, Ta = 25 ± 3°C, data = preset values)
OFF B
ON
A
A (1) Input vertical trigger pulse to pin VIN.
Pulse level (VT) = 3.0 V
(2) Set EW PARABOLA (sub-address: 0A) to minimum (data: 00).
(3) Set PICTURE WIDTH to maximum ( (sub-address: 01, data: FC) and (sub-address:
0C, data: 81) ) and measure Pin 10 (EW FD) voltage VEV (FC).
(4) Set PICTURE WIDTH to minimum ( (sub-address: 01, data: 00) and (sub-address:
0C, data: 80) ) and measure Pin 13 (EW FD) voltage VEV (00).
(5) Calculate change amount VEV using the following formula.
VEV = VEV (FC) − VEV (00)
OFF B
ON
A
A (1) Input vertical trigger pulse to pin VIN.
Pulse level (VT) = 3.0 V
(2) Set PICTURE WIDTH (sub-address: 01) to maximum (data: FC).
(3) Apply external power supply (DC voltage = 7 V) to pin 3 (EHT IN).
(4) Set EW PARABOLA (sub-address: 0A) to minimum (data: 00) and measure Pin 13
(EW FD) amplitude VPB (00).
(5) Set EW PARABOLA (sub-address: 0A) to center (data: 20) and measure Pin 13
(EW FD) amplitude VPB (20).
(6) Set EW PARABOLA (sub-address: 0A) to maximum (data: 3F) and measure Pin 13
(EW FD) amplitude VPB (3F).
(7) Calculate change amount VPB using the following formula.
Pin 13 (EW FD) waveform
VPB = VPB (3F) − VPB (00)
35
2005-08-18