English
Language : 

409-32035 Datasheet, PDF (7/20 Pages) TE Connectivity Ltd – AMP-O-LECTRIC Model G II
409-32035
2.3. Machine Guard
A two-piece guard is installed to provide protection for the operator while maintaining proper visibility of the
work area. The guard swings open to allow easy access for applicator installation and setup. A safety switch on
the guard prevents machine operation if the guard door is open.
3. RECEIVING INSPECTION AND INSTALLATION
3.1. Receiving Inspection
These machines are thoroughly inspected during and after assembly. A final series of inspections is made to
insure the proper machine functioning before packaging and shipping.
To protect against damage that may have occurred during shipment, remove the machine from the crate
(Paragraph 3.2.) and carefully inspect the machine for damage. If damage is evident, file a claim against the
carrier and notify TE immediately.
3.2. Installation
Remove all mounting bolts securing the machine to the shipping pallet. The lift point of the machine is
accessible from the top of the machine cover. Install lift ring (see Figure 7) on top of the machine.
NOTE
Lift ring (M12 x 20 eye bolt) is customer supplied (Ref TE PN 1428156-1).
Lift point for equipment.
CAUTION
Install the lift ring carefully. A 19.05-mm [.75-in.] thread length engagement is required for the lift ring to support the machine.
Attach a suitable hoist to the lift ring, lift the machine, and place it in the selected operating location.
Insert the reel support post into the appropriate hole on top of the machine until the roll pin engages a groove in
the machine frame.
Lift Ring Location
Figure 7
Attach the terminal strip guide included with the machine with the two thumbscrews supplied. Mount the guide
on the left guard for side-feed applicators. Mount the guide on the right guard for end-feed applicators.
Connect the power cord to a suitable electrical supply.
NOTE
The machine will automatically detect the supply voltage and adjust the controller accordingly.
Rev C
7 of 20