Manual Precision
Adjustment Lever
6.4. Guard Insert Adjustment
Figure 12
A guard insert is supplied with the machine. Some applications may require a special insert. See Figure 13 for
available guard inserts.
The guard contains two slots into which the inserts can be placed: the rear slot places the insert close to the
applicator; the front slot places the insert farther away from the applicator. The type of insert used determines
which slot is to be used. An insert placed into the wrong slot cannot be secured in place.
NOTE
Some special inserts are designed to mount in the standard insert slot. These inserts have the threaded holes at the top
corners and should be installed according to the instructions for the standard insert.
Tape Guard Insert
Guard
Insert
“B”
“A”
Standard Guard Insert
“A”
“B”
PART NUMBER
354529-2
1-679532-0
679994-2
679995-2
Rev C
GUARD INSERT
DESCRIPTION
Standard (Away from the Applicator)
Standard (Close to the Applicator) - Shipped with the Machine
Near Tape
Away from Tape
Figure 13
DIMENSION
A
B
7.80 [.307]
6.35 [.250]
6.22 [.245]
5.08 [.200]
6.35 [.250]
6.35 [.250]
8.74 [.344]
6.35 [.250]
16 of 20