English
Language : 

409-32035 Datasheet, PDF (14/20 Pages) TE Connectivity Ltd – AMP-O-LECTRIC Model G II
Lubrication Points
409-32035
Lubrication Points
6. ADJUSTMENTS
Figure 10
The following adjustments are necessary to maintain the machine in operating condition, and to set up the
machine after replacing parts.
DANGER
To avoid personal injury, ALWAYS disconnect electrical and air supplies before performing adjustments.
6.1. Measuring the Shut Height
The shut height is the distance between the bottom surface of the ram post adaptor and the top surface of the
machine base plate as shown in Figure 11.
NOTE
Shut Height Gage PN 679655-2 (see the table in Figure 11) is recommended for measuring shut height (refer to 408-8535 for
instructions on use of the gage).
1. If installed, adjust the manual precision adjustment lever to the “0" setting.
2. Remove the top interlocked cover by pulling straight up.
3. Place a customer supplied (22 mm) wrench on the crankshaft nut. Use the wrench to manually rotate
the crankshaft.
NOTE
Be sure to remove the wrench and re-install the top interlocked cover before operating the machine. The machine will not
run until the cover is in place.
4. Follow the procedure for measuring the shut height as described in 408-8535.
Shut Height Dimension
(See Table Below)
Rev C
Shut Height Gage Machine Part Numbers
Shut Height Dimensions Applicator Type
679655-2
2161400-[ ] AND 2161500-[ ] 135.79 ±0.025 [5.346 ±.0010]
TE-Type
Figure 11
14 of 20