English
Language : 

W83977EG-AW Datasheet, PDF (125/142 Pages) Nuvotem Talema – These products are not designed for use in life support appliances
W83977EF-AW/W83977EG-AW
SYMBOL
PARAMETER
tWGO
Write data to GPIO update
Note : Refer to Microprocessor Interface Timing for Read Timing.
13.3.11 Keyboard/Mouse Timing Parameters
SYMBOL
tSWL
tSWH
tWKUPD
tWKUPW
PARAMETER
PANSWIN# falling edge to PANSWOUT# falling edge
PANSWIN# falling edge to PANSWOUT# Hi-Z
KCLK/MCLK falling edge to PANSWOUT# falling
edge delay
PANSWOUT# active pulse width
MIN.
MIN.
0.5
MAX.
300(Note 1)
MAX.
20
50
200
1
UNIT
ns
UNIT
ns
ns
ns
sec
-123-
Publication Release Date: Apr. 2006
Revision 1.2