4. Other characteristics
4. 1 Temperature characteristics of detection voltage
The shaded area in Figure 26 shows the temperature characteristics of detection voltage in the operation
temperature range.
âVDET [V]
+0.945 mV/°C
âVDET25*1
â0.945 mV/°C
â40
+25
+85
Ta [°C]
*1. âVDET25 is an actual detection voltage value at Ta = +25°C.
Figure 26 Temperature Characteristics of Detection Voltage (Example for âVDET = 2.7 V)
4. 2 Temperature characteristics of release voltage
The temperature change
Î + VDET
ÎTa
of the release voltage is calculated by using the temperature change
Î â VDET
ÎTa
of the detection voltage as follows:
Î + VDET
ÎTa
=
+VDET
âVDET
Ã
Î â VDET
ÎTa
The temperature change of the release voltage and the detection voltage has the same sign consequently.
4. 3 Temperature characteristics of hysteresis voltage
The temperature change of the hysteresis voltage is expressed as
Î + VDET
ÎTa
â
Î â VDET
ÎTa
and is calculated as
follows:
Î + VDET
ÎTa
â
Î â VDET
ÎTa
=
VHYS
âVDET
Ã
Î â VDET
ÎTa