S1003 Datasheet, PDF (1/42 Pages) Seiko Instruments Inc – MANUAL RESET BUILT-IN DELAY CIRCUIT (EXTERNAL DELAY TIME SETTING)
S-1003 Series
www.sii-ic.com
© Seiko Instruments Inc., 2013
MANUAL RESET BUILT-IN DELAY CIRCUIT (EXTERNAL DELAY TIME SETTING)
HIGH-ACCURACY VOLTAGE DETECTOR
Rev.1.0_00
The S-1003 Series is a high-accuracy voltage detector developed using CMOS technology. The detection voltage is fixed
internally with an accuracy of ±1.0% (−VDET ≥ 2.2 V). It operates with current consumption of 500 nA typ.
The release signal can be delayed by setting a capacitor externally. Delay time accuracy is ±15%.
Moreover, since the S-1003 Series includes the manual reset function, the reset signal can be also output forcibly.
Two output forms Nch open-drain output and CMOS output are available.
„ Features
• Detection voltage:
• Detection voltage accuracy:
• Current consumption:
• Operation voltage range:
• Hysteresis width:
• Manual reset function:
• Delay time accuracy:
• Output form:
• Operation temperature range:
• Lead-free (Sn 100%), halogen-free
1.2 V to 5.0 V (0.1 V step)
±1.0% (2.2 V ≤ −VDET ≤ 5.0 V)
±22 mV (1.2 V ≤ −VDET < 2.2 V)
500 nA typ.
0.95 V to 10.0 V
5% ± 2%
MR pin logic active "L", active "H"
±15% (CD = 4.7 nF)
Nch open-drain output (Active "L")
CMOS output (Active "L")
Ta = −40°C to +85°C
„ Applications
• Power supply monitor for microcomputer and reset for CPU
• Constant voltage power supply monitor for TV, Blu-ray recorder and home appliance
• Power supply monitor for portable devices such as notebook PC, digital still camera and mobile phone
„ Packages
• SOT-23-5
• SNT-6A
Seiko Instruments Inc.