English
Language : 

M166 Datasheet, PDF (114/127 Pages) Siemens Semiconductor Group – C16x Family of Siemens 16-Bit CMOS Single-Chip Microcontrollers
30Mar98@15:00h
C166 Family Instruction Set
Instruction Description
XOR
Logical Exclusive OR
XOR
Syntax
Operation
Data Types
Description
XOR
op1, op2
(op1) ← (op1) ⊕ (op2)
WORD
Performs a bitwise logical EXCLUSIVE OR of the source operand speci-
fied by op2 and the destination operand specified by op1. The result is
then stored in op1.
Condition Flags
E
Z
V
C
N
*
*
0
0
*
Addressing Modes
E Set if the value of op2 represents the lowest possible negative number.
Cleared otherwise. Used to signal the end of a table.
Z Set if result equals zero. Cleared otherwise.
V Always cleared.
C Always cleared.
N Set if the most significant bit of the result is set. Cleared otherwise.
Mnemonic
XOR
XOR
XOR
XOR
XOR
Rwn, Rwm
Rwn, [Rwi]
Rwn, [Rwi+]
Rwn, #data3
reg, #data16
XOR
reg, mem
XOR
mem, reg
Format
50 nm
58 n:10ii
58 n:11ii
58 n:0###
56 RR ## ##
52 RR MM MM
54 RR MM MM
Bytes
2
2
2
2
4
4
4
Semiconductor Group
114