5. Electrical Characteristics
5.3.3
Timing of Recovery from Low Power Consumption Modes
Table 5.18 Timing of Recovery from Low Power Consumption Modes (1)
Conditions: VCC = 2.7 V to 5.5 V, AVCC0 = VREFH0 = VCC to 5.5 V, VSS = AVSS0 = VREFL0 = 0 V, Ta = –40 to +105°C
Item
Symbol Min.
Typ. Max.
Unit
Test
Conditions
Recovery time High-speed Crystal connected to Main clock oscillator tSBYMC —
2
from software mode
main clock oscillator operating*2
3
ms Figure 5.30
standby mode*1
External clock input Main clock oscillator tSBYEX —
35
50
μs
to main clock
operating*3
oscillator
Main clock oscillator tSBYPE —
70
95
μs
and PLL circuit
operating*4
LOCO clock oscillator operating
tSBYLO
—
40
55
μs
Note 1. The recovery time varies depending on the state of each oscillator when the WAIT instruction is executed. The recovery time
when multiple oscillators are operating varies depending on the operating state of the oscillators that are not selected as the
system clock source. The above table applies when only the corresponding clock is operating.
Note 2. When the frequency of crystal is 20 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 04h.
Note 3. When the frequency of the external clock is 20 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 00h.
Note 4. When the frequency of PLL is 40 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 00h.
Table 5.19 Timing of Recovery from Low Power Consumption Modes (2)
Conditions: VCC = 2.7 V to 5.5 V, AVCC0 = VREFH0 = VCC to 5.5 V, VSS = AVSS0 = VREFL0 = 0 V, Ta = –40 to +105°C
Item
Symbol Min.
Typ. Max.
Unit
Test
Conditions
Recovery time Middle-speed Crystal connected to Main clock oscillator tSBYMC —
2
from software mode
main clock oscillator operating*2
3
ms Figure 5.30
standby mode*1
External clock input Main clock oscillator tSBYEX —
3
to main clock
operating*3
4
μs
oscillator
Main clock oscillator tSBYPE —
65
85
μs
and PLL circuit
operating*4
LOCO clock oscillator operating
tSBYLO
—
5
7
μs
Note 1. The recovery time varies depending on the state of each oscillator when the WAIT instruction is executed. The recovery time
when multiple oscillators are operating varies depending on the operating state of the oscillators that are not selected as the
system clock source. The above table applies when only the corresponding clock is operating.
Note 2. When the frequency of the crystal is 12 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 04h.
Note 3. When the frequency of the external clock is 12 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 00h.
Note 4. When the frequency of PLL is 12 MHz.
When the main clock oscillator wait control register (MOSCWTCR) is set to 00h.
R01DS0248EJ0110 Rev.1.10
Jan 13, 2016