R01AN1504EJ0100 Datasheet, PDF (30/50 Pages) Renesas Technology Corp – Using the DTC to Perform Continuous Clock | |||
|
◁ |
RL78/G14
Enabling the CSI00 output
⢠Serial output enable register 0 (SOE0)
Using the DTC to Perform Continuous Clock
Synchronous Serial Communication
Symbol 15 14 13 12 11 10 9 8 7 6 5 4
3
2
1
0
SOE0 0 0 0 0 0 0 0 0 0 0 0 0 SOE03 SOE02 SOE01 SOE00
Value â â â â â â â â â â â â
Ã
Ã
Ã
1
⢠Bit 0
SOE00
bit
0
1
Serial output enable/stop of channel 0
Stops output by serial communication operation
Enables output by serial communication operation
Enabling to start the CSI00 communication operation
⢠Serial channel start register 0 (SS0)
Symbol 15 14 13 12 11 10 9 8 7 6 5 4
3
2
1
0
SS0 0 0 0 0 0 0 0 0 0 0 0 0 SS03 SS02 SS01 SS00
Value â â â â â â â â â â â â
Ã
Ã
Ã
1
⢠Bit 0
SS00 bit
0
1
Operation start trigger of channel 0
No trigger operation
Sets the SE00 bit to 1 and enters the communication wait status
For details on register setting, refer to the RL78/G14 Userâs Manual: Hardware.
Legend symbol:
Ã: Unused bit; blank cell: unchanged bit; â: reserved bit or unallocated bit
R01AN1504EJ0100 Rev. 1.00
Feb. 14, 2014
Page 30 of 47
|
▷ |