4.1.2. Control Word R1
Name
CPCUR
PFDPOL
LDERR
LDTIME
RSSIGAIN
VCORANGE
VCOCUR
VCOBUF
PRESCUR
SHOWLD
Bits
[1:0]
[2]
[3]
[5:4]
[6]
[7]
[8]
[9]
[10]
[11]
Description
charge pump current setting
00 100µA
01 400µA
10 400µA static down
11 400µA static up
PFD output polarity
0 negative
1 positive
lock detector time error
0 15ns
1 30ns
lock detection time
00 2/fR
01 4/fR
10 8/fR
11 16/fR
minimum time span before lock in
fR is the reference oscillator frequency fRO divided by R, see section 4.1.5 (R4)
sensitivity of RSSI voltage
0 low gain
1 high gain
(~39mV/dB)
(~51mV/dB)
VCO range
0 3V supply
1 5V supply
VCO range setting for different VCCs.
VCO core current
0 450µA
1 520µA
VCO buffer current
0 900µA
1 1040µA
prescaler 32/33 reference current
0 20µA
1 30µA
30µA may be used for fRF = 868/915MHz
function of LDRSSIL bit
0 RSSIL (RSSI low flag)
1 LD (lock detection flag)
select output data of LDRSSIL, see section 4.1.8 (R7)
#default
#default
#default
#default
#default
#default
#default
#default
#default
#default
REVISION 014 – AUGUST, 2016