MAX11008 Datasheet, PDF (52/67 Pages) Maxim Integrated Products – Dual RF LDMOS Bias Controller with Nonvolatile Memory
Dual RF LDMOS Bias Controller with
Nonvolatile Memory
Table 12. Alarm Software Configuration Register
DATA BITS
D[15:12]
D11*
D10*
D9*
D8*
D7
D6
D5
D4
D3
D2
D1
D0
X = Don’t care.
*Write only.
BIT NAME
Unused
A2AVG
T2AVG
A1AVG
T1AVG
TALARM2
TWIN2
IALARM2
IWIN2
TALARM1
TWIN1
IALARM1
IWIN1
RESET STATE
X
Unused bits.
FUNCTION
Channel 2 APC averaging and filtering bit.
Set to 1 to enable the APC averaging and filtering function for channel 2.
0
The source of the sample is controlled by the APCSRC2 field in the Software
Configuration register.
Channel 2 temperature averaging and filtering bit.
0
Set to 1 to enable the temperature averaging and filtering function for
channel 2. The source of the sample is controlled by the TSRC2 field in the
Software Configuration register.
Channel 1 APC averaging and filtering bit.
0
Set to 1 to enable the APC averaging and filtering function for channel 1.
The source of the sample is controlled by the APCSRC1 field in the Software
Configuration register.
Channel 1 temperature averaging and filtering bit.
0
Set to 1 to enable the temperature averaging and filtering function for
channel 1. The source of the sample is controlled by the TSRC1 field in the
Software Configuration register.
0
Channel 2 temperature alarm enable bit. Set TALARM2 to 1 to enable the
channel 2 temperature alarm.
Channel 2 temperature alarm window bit. Set to 0 for hysteresis mode, and
0
set to 1 for window mode. See the Hysteresis Mode and Window Mode
sections.
0
Channel 2 current alarm enable bit. Set IALARM2 to 1 to enable the channel
2 current alarm.
0
Channel 2 current alarm window bit. Set to 0 for hysteresis mode, and set to
1 for window mode. See the Hysteresis Mode and Window Mode sections.
0
Channel 1 temperature alarm enable bit. Set TALARM1 to 1 to enable the
channel 1 temperature alarm.
Channel 1 temperature alarm window bit. Set to 0 for hysteresis mode, and
0
set to 1 for window mode. See the Hysteresis Mode and Window Mode
sections.
0
Channel 1 current alarm enable bit. Set IALARM1 to 1 to enable the channel
1 current alarm.
0
Channel 1 current alarm window bit. Set to 0 for hysteresis mode, and set to
1 for window mode. See the Hysteresis Mode and Window Mode sections.
52 ______________________________________________________________________________________