E3A-MA3A-H11 Datasheet, PDF (42/48 Pages) Magnetrol International, Inc. – Digital E3 Modulevel with HART® and PACTware™ Communications Liquid Level Displacer Transmitter
3.7 Model Numbers
3.7.1 E3x for Non-Steam Service
DESIGN TYPE
E 3 Standard Construction Electronic Modulevel
MOUNTING AND CHAMBER MATERIALS
Flanged top Œ
steel 316 SS
A
B
Cage side/bottom
steel 316 SS 
C
D
Cage side/side
steel 316 SS 
E
F
ΠAdjustable 8-foot hanger cable, part number 32-3110-001, required when
distance from flange face to top of displacer must be greater than 7.31".
 Bolting material is alloy steel.
SPECIFIC GRAVITY AND PROCESS TEMPERATURE
Integral or Remote
Transmitter Mounting
1&4
1&4
1&4
1&4
3 & 6 Use with Mounting/Temp. codes (9th Digit)
+300° F
(+150° C)
+400° F
(+200° C)
+450° F
(+230° C)
+550° F
(+290° C)
+600° F
(+315° C)
maximum process temperature
J
A
M
D
M 0.23 – 0.54 specific gravity (up to 600 lbs)
K
B
N
E
N
0.55 – 1.09 specific gravity (all pressures)
L
C
P
F
P
1.10 – 2.20 specific gravity (up to 600 lbs)
PROCESS CONNECTION SIZE & TYPE
External Cage
11⁄2"
2"
Top Mount
3"
4"
6"
Type
A
E
n/a n/a n/a NPT
R
F
n/a n/a n/a SW
P
Q
G
H
K Flange
CHAMBER PRESSURE CLASS
ANSI Flange rating
150# RF
3
300# RF
4
600# RF
5
900# RF 1500# RF  2500# RF Ž
6
7
8
Ž Pressure rating limited by enclosing tube to 5150 psi @ 100°F
 For stainless steel construction on 1500# and 2500# models, consult factory
LEVEL RANGE
All Pressures
14
32
48
356 813 1219
A
B
C
60
1524
D
72
1829
E
600# or below
84
96 108
2134 2438 2743
F
G
H
120
3048
I
Inches
mm
Code
TRANSMITTER – ELECTRONICS (see opposite page)
E3
42