3.6 Specifications
3.6.1 Functional
System Design
Measurement Principle
Buoyancy – continuous displacement utilizing a precision range spring
Input
Measured Variable
Level, determined by LVDT core movement affected by
buoyancy force changes on continuous displacer
Physical Range
Up to 120" (300 cm) based on displacer length (C/F for longer ranges)
Output
Type
Analog:
4 to 20 mA direct or reverse with HART digital signal
Range
Analog:
3.8 to 20.5 mA useable, 22.5 mA maximum
Digital:
0 to 100%
Resolution
Analog:
0.01 mA
Digital:
0.1%
Level units:
0.01 inch
Loop Resistance (maximum)
620 ohms @ 24 VDC
Diagnostic Alarm
3.6, 22 mA or HOLD selectable (Complies with NAMUR NE 43)
Damping
Adjustable 0-45 seconds
Sampling Rate
Transmitter 15 times per second
User Interface
Keypad
3-button menu-driven data entry and system security
Indication
2-line × 8-character LCD display
Digital Communication
HART Version 5.x compatible
Power
Voltage (measured at instrument terminals)
11–36 VDC (Direct Current) This device provides only Functional Isolation
Current
22.5 mA maximum
Housing
Material
Aluminum A356-T6 (<0.20% copper), optional 316 stainless steel
Cable Entry
3⁄4" NPT and M20
Ingress Protection
TYPE 4X, IP66
Chamber
Materials
Carbon steel
316/316L stainless steel
Wetted parts
304/304L and 316/316L (900# and greater) and Inconel® (spring)
316/316L (600# and less) and Inconel (spring)
Process connections
Tank Top:
3", 4", 6" ANSI Flange
Chambered:
11⁄2", 2" NPT
11⁄2", 2" Socketweld
11⁄2", 2" ANSI Flanges
Process Conditions
Process temperature range Œ
Steam applications:
-20° to +500° F (-29° to +260° C)
Non-steam applications:
-20° to +600° F (-29° to +315° C) 
Process pressure range
5100 psig @ +100° F
(351 bar @ +38° C)
Œ Maximum process temperatures are based on ambient temperatures less than or equal to +120° F (+49° C).
Higher ambient temperatures require reduced process temperatures.
 Consult factory for low temperature applications down to -330° F (-200° C).
38
48-635 E3 Modulevel Displacer Level Transmitter