English
Language : 

E3A-MA3A-H11 Datasheet, PDF (36/48 Pages) Magnetrol International, Inc. – Digital E3 Modulevel with HART® and PACTware™ Communications Liquid Level Displacer Transmitter
3.5.2 User Calibration Procedure
The E3 Modulevel is calibrated at the factory, so it normally requires only configuration by the user in
the field. Should the E3 require replacement of any parts in the field, a user calibration must be per-
formed after changing out any of the following original parts: Bezel assembly, LVDT assembly, range
spring, stem assembly, or displacer. The following procedure should be followed when performing a
user calibration in the field. Note: User calibration should be performed at normal operating conditions.
1. Move liquid level on displacer to desired low level point. Using keypad and LCD display, scroll down to DispFact.
2. Press to access data entry mode, down arrow until “Yes” is displayed and Enter again. The factory menu is
now accessible.
3. Scroll down to CalSelct.
4. Press , then until “User” is displayed and again.
5. Scroll down to SnrCalLo.
6. Press , then and simultaneously and again. The current liquid level has been captured as the low
level point.
7. Scroll down to LvlCalLo. The default value is 0.00. If a different level value is desired at this point, press
, use the and keys to choose the desired value and press again.
8. Move the liquid level on displacer to the desired high level point. Scroll to SnrCalHi.
9. Press , then and simultaneously and again. The current liquid level has been captured as the high
level point.
10. Scroll down to LvlCalHi. The default value is the displacer length. If a different level value is desired at this point,
press , use the and keys to choose the desired value and press again. The user calibration is complete.
3.5.3 Mechanical Replacement Parts
Cage Temp.
Pressure Config.
Rating 4th digit
Spring SG
Range
E-tube Kits
CSA, FM, ATEX, IEC
Carbon Steel Carbon Steel
CSA, FM,
ATEX, IEC,
316 SS
Stem Kit*
Spring Kits*
Inconel®
316 SS
0.23 – 0.54
089-5565-004 089-5340-002
A, B, C 0.55 – 1.09 089-5958-017 089-5958-002 089-5958-006 089-5565-003 089-5340-005
1.10 – 2.20
0.23 – 0.54
089-5565-003 089-5340-008
n/a
089-5565-008 089-5340-003
D, E, F 0.55 – 1.09 089-5958-019 089-5958-004 089-5958-008 089-5565-007 089-5340-006
150#,
300#
& 600#
ANSI
J, K, L
M, N, P
Temp ≤
+450°F
(+230°C)
M, N, P
Temp ≥
+500°F
(+260°C)
B
1.10 – 2.20
0.23 – 0.54
0.55 – 1.09 089-5958-005
1.10 – 2.20
0.23 – 0.54
0.55 – 1.09 089-5958-018
1.10 – 2.20
0.23 – 0.54
0.55 – 1.09 089-5958-018
1.10 – 2.20
089-5958-020
089-5958-001
089-5958-003
089-5958-003
089-5958-010
089-5958-005
089-5958-007
089-5958-007
089-5958-014
089-5565-007
089-5565-002
089-5565-001
089-5565-001
089-5565-006
089-5565-005
089-5565-005
089-5565-006
089-5565-005
089-5565-005
089-5565-004
089-5340-009
089-5340-002
089-5340-005
089-5340-008
089-5340-002
089-5340-005
089-5340-008
089-5340-003
089-5340-006
089-5340-009
089-5340-001
089-5340-004
089-5340-007
n/a
n/a
900#
ANSI
E
089-5958-022 089-5958-012 089-5958-016 089-5565-008
0.55 – 1.09
K
089-5958-013 089-5958-009 089-5958-013 089-5565-002
N
089-5958-021 089-5958-011 089-5958-015 089-5565-006
089-5340-010
n/a
B
089-5958-020 089-5958-010
089-5565-004
1500#
E
089-5958-022 089-5958-012
089-5565-008
& 2500#
0.55 - 1.09
n/a
ANSI
K
089-5958-013 089-5958-009
089-5565-002
N
089-5958-021 089-5958-011
089-5565-006
* Field replacement of this part requires a user calibration of the repaired unit.
36
48-635 E3 Modulevel Displacer Level Transmitter