English
Language : 

DG-IRMCK203 Datasheet, PDF (48/67 Pages) International Rectifier – Application Developer’s Guide
Byte
Offset
7
0x7E
0x7F
IRMCK203 Application Developer’s Guide
Bit Position
6
5
4
3
2
1
0
NumRetries
ParkIRet
StartupRetrial Write Register Map
Field
Name
RetryTm
ParkTmRet
FlxThrL
FlxThrH
NumRetries
ParkIRet
Access Field Description
(R/W)
This parameter provides the adjustment to the sampling instant for
W determination of start failure. The sampling instant starts when
Closed_Loop = 1. Scaling 1 count = 1.966 msec. Please do not
modify this parameter without consulting a motor drive FAE.
During motor start-up, dc current is injected to the motor for
W maximization of startup torque per ampere rating. ParkTm controls
the duration of dc current injection. However, users are able to use a
longer duration after two or more restarts by setting this parameter
(ParkTmRet scaling 255 = 4 secs.). This is done to increase the
chance of a successful start-up.Start-up failure may be caused by
increased shaft friction. After first start-up retry, the parking time can
be increased to improve parking performance.
W The low flux threshold level for determining a successful startup
(scaling: 129 = 100% flux). Please do not modify this parameter
without consulting a motor drive FAE.The low flux threshold level for
determining a successful startup.
W The upper flux threshold level for determining a successful startup
(scaling: 64 = 100% flux). Please do not modify this parameter
without consulting a motor drive FAE.The high flux threshold level for
determining start-up failure.
If start-up fails, the user can program start-up retrial. This parameter
W determines the number of start-up retries. A value of zero will disable
startup retrial. The maximum number of retries is 15.
During motor start-up, dc current is injected to the motor for
W maximization of startup torque per ampere rating. Users are able to
use a higher level of dc current injection (ParkIRet scaling 255 =
Motor Rated Amp * 0.866) after two or more restarts. This is done to
increase the chance of a successful start-up.Start-up failure may be
caused by increased shaft friction. After first start-up retry, the
parking current can be increased to improve parking performance.
StartupRetrial Write Register Field Definitions
This document is the property of International Rectifier and may not be copied or distributed without expressed consent.