English
Language : 

DG-IRMCK203 Datasheet, PDF (47/67 Pages) International Rectifier – Application Developer’s Guide
Byte
Offset
7
0x69
0x78
IRMCK203 Application Developer’s Guide
Bit Position
6
5
4
3
2
1
0
WeThr (MSBs
(W)
ParkTm
(W)
StartupAngleEstimator Write Register Map
Field
Name
ParkI
DiagnosticCtrl
PhsLosFlt
Disable
Use2xFrqScale
ZeroSpdFlt
Disable
WeThr
ParkTm
Access Field Description
(R/W)
W DC current injection level during motor parking (start-up mode).
W 1 (0001) – Enable Parking diagnostic
2 (0010) – Enable start-up diagnostic
5 (0101) – Enable current regulator diagnostic
9 (1001) – Enable volts Hertz diagnostic
W Enable/disable phase loss fault: 0 = Enable Phase Loss Fault; 1
= Disable Phase Loss Fault
W Selects speed scaling:
0 - Norminal speed scale
1 - Reduce speed feedback scaling by half
Please do not modify this parameter without consulting motor
control FAEs
W Zero speed fault enable/disable:
0 - Enbale Zero Speed Fault
1 - Disable Zero Speed Fault
W Frequency threshold level (switch over from open-loop to closed-
loop mode).
W Time duration of parking mode. 255 = 4 sec
StartupAngleEstimator Write Register Field Definitions
4.2.12 StartupRetrial Registers (Write Registers)
Byte
Offset
Bit Position
7
6
5
4
3
2
1
0
0x1E
RetryTm (LSBs)
0x1F
RetryTm (MSBs)
0x79
ParkTmRet
0x7B
FlxThrL
0x7C
FlxThrH
This document is the property of International Rectifier and may not be copied or distributed without expressed consent.
47