English
Language : 

90E36 Datasheet, PDF (76/79 Pages) Integrated Device Technology – Poly-Phase High-Performance Wide-Span Energy Metering IC
90E36
POLY-PHASE HIGH-PERFORMANCE WIDE-SPAN ENERGY METERING IC
7.6 VOLTAGE SAG AND PHASE LOSS TIMING
Voltage
+ threshold
- threshold
IRQ (if enabled)
11ms window
Sag/Phase Loss condition found
in two consecutive windows
Figure-28 Voltage Sag and Phase Loss Timing Diagram
time
Assert of
Voltage Sag / Phase Loss
Electrical Specification
76
December 9, 2011