90E36 Datasheet, PDF (70/79 Pages) Integrated Device Technology – Poly-Phase High-Performance Wide-Span Energy Metering IC
90E36
POLY-PHASE HIGH-PERFORMANCE WIDE-SPAN ENERGY METERING IC
7.2 METERING/ MEASUREMENT ACCURACY
7.2.1 METERING ACCURACY
Metering accuracy or energy accuracy is calculated with relative
error:
γ
=
Emea − Ereal
Ereal
×100%
Where Emea is the energy measured by the meter, Ereal is the actual
energy measured by a high accurate normative meter.
Table-15 Metering Accuracy for Different Energy within the Dynamic Range
Energy Type
Energy Pulse
ADC Range
When Gain=1
Metering Accuracynote 1
Active energy
CF1
(Per phase and all-phase-sum)
PF=1.0 120µV-720mV
PF=0.5L, 180µV-720mV
0.1%
PF=0.8C, 150µV-720mV
Reactive energy
CF2
(Per phase and all-phase-sum)
sinФ=1.0 120µV-720mV
sinФ=0.5L, 180µV-720mV
0.2%
sinФ=0.8C, 150µV-720mV
Apparent energy
CF2
(Per phase and arithmetic all-phase-sum)
600µV-720mVnote 2
0.2%
Apparent energy (Vector sum)
CF2
120µV-720mV
0.5%
Fundamental active energy
CF3
(Per phase and all-phase-sum)
PF=1.0 120µV-720mV
PF=0.5L, 180µV-720mV
0.2%
PF=0.8C, 150µV-720mV
Harmonic active energy
CF4
(Per phase and all-phase-sum)
PF=1.0 120µV-720mV
PF=0.5L, 180µV-720mV
0.5%
PF=0.8C, 150µV-720mV
Note 1: All the parameters in this table is tested on IDT’s test platform.
Note 2: Apparent energy is tested using active energy with unity power factor since there’s no standard for apparent energy. Signal below 600 µV is not tested.