11
512Mbit (32Mx16bit) Mobile SDR Memory
HY5S7B6LF(P) Series
BURST TERMINATE
The BURST TERMINATE command is used to truncate read bursts (with autoprecharge disabled). The most recently
registered READ command prior to the BURST TERMINATE command will be truncated, as shown in the Operation sec-
tion of this datasheet. Note the BURST TERMINATE command is not bank specific. This command should not be used
to terminate write bursts.
CLK
CKE
CS
RAS
CAS
WE
A0 ~ A12
BA0, 1
High-Z
Don't Care
BURST TERMINATE COMMAND
Rev 1.0 / Jan. 2007