English
Language : 

HD61830 Datasheet, PDF (37/43 Pages) Hitachi Semiconductor – LCDC (LCD Timing Controller)
HD61830/HD61830B
Timing Characteristics
HD61830B Clock Operation (VCC = 5 V ±10%, GND = 0V, Ta = –20 to +75°C)
Item
Symbol Min
Typ
External clock operating frequency fcp
100
—
External clock duty
Duty
47.5
50
External clock rise time
t rcp
—
—
External clock fall time
t fcp
—
—
SYNC output hold time
t HSYO
30
—
SYNC output delay time
t DSY
—
—
SYNC input hold time
t HSYI
10
—
SYNC input set-up time
t SSY
—
—
Notes: 1. Applied to external clock input terminal.
Th
Max
Unit
2400
kHz
52.5
%
25.0
ns
25.0
ns
—
ns
210
ns
—
ns
180
ns
Tl
Notes
1
1
1
1
2, 3
2, 3
2
2
Oscillator
CR
0.7 VCC
0.5 VCC
0.3 VCC
trcp
2. Applied to SYNC terminal.
tfcp
Duty cycle = Th × 100%
Th + Tl
CR
SYNC
(Output:
at master
mode)
0.7 VCC
0.3 VCC
tDSY
tHSYO
0.7 VCC
tHSYI
0.3 VCC
tSSY
tDSY
tHSYO
tHSYI
tSSY
SYNC
(Input:
at slave
mode)
3. Testing load circuit.
Test point
0.7 VCC
0.3 VCC
CL
CL = 30 pF
(CL includes jig capacitance)
37