English
Language : 

XRT75R03D_06 Datasheet, PDF (81/135 Pages) Exar Corporation – EXAR DATA SHEET FORMAT TEMPLATES
REV. 1.0.4
XRT75R03D
THREE CHANNEL E3/DS3/STS-1 LINE
BIT NUMBER
NAME
4
Insert PRBS Error
3
Unused
2
TAOS
TYPE
R/W
R/O
R/W
DEFAULT
VALUE
DESCRIPTION
0 Insert PRBS Error - Channel_n:
A "0 to 1" transition within this bit-field configures the PRBS
Generator (within the Transmit Section of Channel_n) to
generate a single bit error within the outbound PRBS pat-
tern-stream.
NOTES:
1. This bit-field is only active if the PRBS Generator
and Receiver have been enabled within the
corresponding Channel.
2. After writing the "1" into this register, the user must
execute a write operation to clear this particular
register bit to "0" in order to facilitate the next "0 to
1" transition in this bit-field.
0
0 Transmit All OneS Pattern - Channel_n:
This READ/WRITE bit-field is used to command the Trans-
mit Section of Channel_n to generate and transmit an
unframed, All Ones pattern via the DS3, E3 or STS-1 line
signal (to the remote terminal equipment).
Whenever the user implements this configuration setting
then the Transmit Section will ignore the data that it is
accepting from the System-side equipment and overwrite
this data with the "All Ones" Pattern.
0 - Configures the Transmit Section to transmit the data that
it accepts from the System-side Interface.
1 - Configures the Transmit Section to generate and trans-
mit the Unframed, All Ones pattern.
77