English
Language : 

XRT75R03D_06 Datasheet, PDF (53/135 Pages) Exar Corporation – EXAR DATA SHEET FORMAT TEMPLATES
XRT75R03D
REV. 1.0.4
THREE CHANNEL E3/DS3/STS-1 LINE
6.4.3 Muting the Recovered Data with LOS condition:
When the LOS condition is declared, the clock recovery circuit locks into the reference clock applied to the
ExClk_n pin and output this clock on the RxClk_n output.In Single Frequency Mode (SFM), the clock recovery
locks into the rate clock generated and output this clock on the RxClk_n pins. The data on the RPOS_n and
RNEG_n pins can be forced to zero by pulling the LOSMUT pin “High” (in Hardware Mode) or by setting the
LOSMUT_n bits in the individual channel control register to “1” (in Host Mode).
NOTE: When the LOS condition is cleared, the recovered data is output on RPOS_n and RNEG_n pins.
7.0 JITTER:
There are three fundamental parameters that describe circuit performance relative to jitter:
• Jitter Tolerance (Receiver)
• Jitter Transfer (Receiver/Transmitter)
• Jitter Generation
7.1 JITTER TOLERANCE - RECEIVER:
Jitter tolerance is a measure of how well a Clock and Data Recovery unit can successfully recover data in the
presence of various forms of jitter. It is characterized by the amount of jitter required to produce a specified bit
error rate. The tolerance depends on the frequency content of the jitter. Jitter Tolerance is measured as the
jitter amplitude over a jitter spectrum for which the clock and data recovery unit achieves a specified bit error
rate (BER). To measure the jitter tolerance as shown in Figure 21, jitter is introduced by the sinusoidal
modulation of the serial data bit sequence.
FIGURE 22. JITTER TOLERANCE MEASUREMENTS
Pattern
Data
Generator
Modulation
Freq.
FREQ
Synthesizer
DUT
XRT75VL03D
Clock
Error
Detector
Input jitter tolerance requirements are specified in terms of compliance with jitter mask which is represented as
a combination of points.Each point corresponds to a minimum amplitude of sinusoidal jitter at a given jitter
frequency.
7.1.1 DS3/STS-1 Jitter Tolerance Requirements:
Bellcore GR-499 CORE, Issue 1, December 1995 specifies the minimum requirement of jitter tolerance for
Category I and Category II. The jitter tolerance requirement for Category II is the most stringent. Figure 22
shows the jitter tolerance curve as per GR-499 specification.
49