English
Language : 

20-101-1051 Datasheet, PDF (43/165 Pages) List of Unclassifed Manufacturers – C-Programmable Core Module with NAND Flash Mass Storage and Ethernet
A program “runs” in either mode, but can only be downloaded and debugged when the
RCM3365/RCM3375 is in the Program Mode.
Refer to the Rabbit 3000 Microprocessor User’s Manual for more information on the pro-
gramming port.
4.3.2 Standalone Operation of the RCM3365/RCM3375
The RCM3365/RCM3375 must be programmed via the Prototyping Board or via a similar
arrangement on a customer-supplied board. Once the RCM3365/RCM3375 has been pro-
grammed successfully, remove the serial programming cable from the programming con-
nector and reset the RCM3365/RCM3375. The RCM3365/RCM3375 may be reset by
cycling the power off/on or by pressing the RESET button on the Prototyping Board. The
RCM3365/RCM3375 module may now be removed from the Prototyping Board for end-
use installation.
CAUTION: Disconnect power to the Prototyping Board or other boards when removing
or installing your RCM3365/RCM3375 module to protect against inadvertent shorts
across the pins or damage to the RCM3365/RCM3375 if the pins are not plugged in
correctly. Do not reapply power until you have verified that the RCM3365/RCM3375
module is plugged in correctly.
User’s Manual
37