20-101-1051 Datasheet, PDF (140/165 Pages) List of Unclassifed Manufacturers – C-Programmable Core Module with NAND Flash Mass Storage and Ethernet
A lithium battery with a nominal voltage of 3 V and a minimum capacity of 165 mA·h is
recommended. A lithium battery is strongly recommended because of its nearly constant
nominal voltage over most of its life.
The drain on the battery by the RCM3365/RCM3375 is typically 6 µA when no other power
is supplied. If a 165 mA·h battery is used, the battery can last about 3 years:
1---6---65-----µm----A-A----·--h- = 3.1 years.
The RCM3365/RCM3375 module does not drain the battery while it is powered up
normally.
Cycle the main power off/on on the RCM3365/RCM3375 after you install a backup battery
for the first time, and whenever you replace the battery. This step will minimize the current
drawn by the real-time clock oscillator circuit from the backup battery should the
RCM3365/RCM3375 experience a loss of main power.
NOTE: Remember to cycle the main power off/on any time the RCM3365/RCM3375 is
removed from the Prototyping Board or motherboard since that is where the backup
battery would be located.
Rabbit’s Technical Note TN235, External 32.768 kHz Oscillator Circuits, provides addi-
tional information about the current draw by the real-time clock oscillator circuit.
D.1.2 Battery-Backup Circuit
Figure D-2 shows the battery-backup circuit.
VRAM
VOSC
External Battery
VBAT-EXT
D1 R46
150 kW
R3
100 W
R7
47 kW
C2
100 nF
C5
10 nF
Figure D-2. RCM33365/RCM3375 Backup Battery Circuit
The battery-backup circuit serves three purposes:
• It reduces the battery voltage to the SRAM and to the real-time clock, thereby limiting
the current consumed by the real-time clock and lengthening the battery life.
• It ensures that current can flow only out of the battery to prevent charging the battery.
• A voltage, VOSC, is supplied to U1, which keeps the 32.768 kHz oscillator working
when the voltage begins to drop.
134