English
Language : 

N2893A Datasheet, PDF (3/29 Pages) List of Unclassifed Manufacturers – InfiniiVision Oscilloscope Probes and Accessories
03 | Keysight | InfiniiVision Oscilloscope Probes and Accessories - Data Sheet
Probe Compatibility Table
For ordering information when replacing your probe or probe accessory: Refer directly to the page number listed in the table of
contents for your probe model.
To assist you in selecting the proper probe for your application: Use our probe compatibility table below to find the probes that are
recommended for use with your 2000 X-, 3000 X-, 4000 X-, 6000 X-, 5000, 6000, and 7000 Series InfiniiVision oscilloscope.
Probe type
Passive probes,
page 4
Probe model
N2862B 10:1 150 MHz
(included in 70/100 MHz models)
N2863B 10:1 300 MHz
(included in 200 MHz models)
N2890A 10:1 500 MHz
(included in 350/500 MHz/1 GHz models)
N2894A 10:1 700 MHz (included in 4000 X models)
MSO/DSO
2000 X1
Recommended
MSO/DSO
3000 X
Recommended
Compatible
Compatible
N2889A 1:1/10:1 350 MHz
High-voltage passive
10076C 4 kV
probes, page 7
N2771B 30 kV
1130A - 1134A 1.5 GHz - 7 GHz
Differential active probes, N2750A - N2752A 1.5 GHz - 6 GHz
page 8
1141A 200 MHz (use with 1142A)
N2791A 25 MHz
N2891A 70 MHz
N2790A 100 MHz (with AutoProbe)
N2792A 200 MHz
N2818A 200 MHz (with AutoProbe)
N2793A 800 MHz
N2819A 800 MHz (with AutoProbe)
N2804A 300 MHz
N2805A 200 MHz
Single-ended active probes, N2795A 1 GHz (with AutoProbe)
page 15
N2796A 2 GHz (with AutoProbe)
N2797A 1.5 GHz (with AutoProbe)
N7020A 2 GHz
MSO logic probes,
01650-61607 16-channel
page 17
N6459-60001 8-channel MSO cable
(included in 2000 X-Series MSOs)
N6450-60001 16-channel MSO cable
(included in 3000 and 4000 X-Series MSOs)
N2756A 16-Channel MSO cable
(included in 6000 X-Series MSOs)
Current probes,
1146B 100 kHz
page 19
N2780B 2 MHz (use with N2779A)
N2781B 10 MHz (use with N2779A)
N2782B 50 MHz (use with N2779A)
N2783B 100 MHz (use with N2779A)
1147B 50 MHz (with AutoProbe)
N2893A 100 MHz (with AutoProbe)
N2820A 3 MHz/50 uA High Sensitivity,
2 channel (with AutoProbe)
N2821A 3 MHz/50 uA High Sensitivity,
1 channel (with AutoProbe)
Recommended
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Recommended
Incompatible
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Incompatible
Recommended
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
1.  The 2000 X-Series does not support AutoProbe interface active probes.
2.  The 4000 X- and 6000 X-Series comes with the Infiniium AutoProbe interface for higher probe power support.
3.  Recommended with 4000 X-Series only.
MSO/DSO
4000 X/6000 X2
Recommended
Compatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended3
Recommended3
Recommended
Recommended
Recommended
Recommended3
Recommended
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended